Test Methods · CDV Vacuum Chambers

Package Leak Testing Methods

Package leak testing methods share one idea: you lower the pressure around the package, or raise it inside, and watch what the package does.

With a CDV vacuum chamber, what changes from one method to the next is the control module and sometimes an accessory, not the principle. This page helps you pick the method for your package and sends you to the detailed guide for each one. New to the topic? Start with the package leak tester guide.

Wet + DryTest Methods ASTM D3078 · F2096Bubble Standards FreeSample Test
Start with your package

Which Method for Which Package

Start from what is inside the package and what you need to know. If your package is not here, send us a sample.

Seal strength of a pouch

Pouch seal opening under vacuum shows the pressure at which the seal opens. See below.

Not sure which standard applies to your product? The series on leak testing methods by package type compares them by package.

Compare methods

Package Leak Testing Methods Compared

The same chamber runs all of these methods. What differs is whether the package needs gas inside, what you observe, and how far the result can be trusted on its own.

MethodStandardGas needed inside the pack?What you seeResult type
Immersion bubble test (bubble emission test)ASTM D3078YesBubbles from the leak point under waterVisual, probabilistic
Dry testNo standard namedNoLiquid or product on a paper towelVisual
Internal pressurizationASTM F2096NoBubbles from a pressurized pack under waterVisual, probabilistic
Altitude simulationASTM D6653Depends on the packHow the pack behaves at reduced pressureNot a leak test by itself
Rigid container transport integrityASTM D4991Empty rigid containersLeakage under vacuumMethod-dependent
Dye ingressUSP <1207> (reference)NoDye inside the packageVisual, probabilistic
Pouch seal openingNo standard namedYesThe vacuum at which the seal opensSeal strength, destructive

Technical note: visual methods depend on the operator and are probabilistic in the USP <1207.2> sense. They are not a substitute for a deterministic method such as vacuum decay (ASTM F2338) when your risk assessment asks for one. See probabilistic and deterministic methods.

Bubble and dry tests

Package Leak Detection

Samples without liquid. Immersion testing to observe bubbles escaping through leaks in the packaging material or seal. This is the bubble emission test: gas inside the pack expands under vacuum, and if a path exists it leaves as a stream of bubbles under water.

Samples containing liquid. Dry testing, without immersion, to observe liquid spills or seepage. A white paper towel under the sample shows where product crosses a seal.

Detection is visual and depends on the operator's interpretation, so the vacuum level and hold time must be validated with known defects.

Packs with little headspace

Internal Pressurization for Vacuum-Packed Products

The additional kit allows compressed air to be injected through a needle for immersion testing. It suits packs with little or no usable headspace, such as vacuum-packed food, sachets and stick packs, and it shows where the pack leaks. The test is destructive.

Reduced pressure

Atmospheric Pressure Variation

Applications under reduced atmospheric pressure and, optionally, positive pressure. Ask about the configuration suitable for your test.

Seal strength

Pouch Seal Opening

Vacuum is applied until the seal ruptures. The result shows the pressure at which a seal opens, which also helps you set a safe vacuum level for the other tests on this page. The test is destructive.

Sterile and pharmaceutical packs

Dye Ingress and Pharmaceutical Methods

When the question is whether a liquid can enter a sterile package, a dye ingress test is used instead of, or together with, bubble emission.

Equipment and other uses

Chambers, Control Modules and Other Uses

The method is set by the control module and the accessories; the chamber sets the size of the sample.

Frequently Asked Questions

Package Leak Testing Methods FAQ

The main methods are the immersion bubble test (ASTM D3078), the dry test for liquid-filled packs, internal pressurization in a water bath (ASTM F2096), reduced-pressure simulation (ASTM D6653), pouch seal opening and dye ingress. A CDV vacuum chamber runs them with the right control module and accessories. Pick the method by what is inside the package and what you need to know.

A dry test, without immersion: lay the sample on a white paper towel, apply vacuum and watch for spills or seepage. Immersion rarely suits liquids, gels or pastes, because little gas forms bubbles and outside water can mask a weep.

The internal pressurization kit. It injects compressed air through a needle while the pack is under water. The kit's inlet accepts a maximum of 2 bar (29 psi) and is supplied with a pressure reducer.

No. Detection is visual and depends on the operator's interpretation. Validate the vacuum level and hold time with packs that have known defects, and write them into your procedure.

It depends on the method. Immersion wets the pack, internal pressurization punctures it, seal opening ruptures the seal, and a dry test can leave a pack that passed intact. Plan your sample size around the packs you will lose.

Yes. The test is free: send your samples and you receive a video of the tests performed and recommendations on test parameters.

Free test

Send us your samples

Receive a video of the tests performed and recommendations on test parameters.