Package Leak Testing Methods
Package leak testing methods share one idea: you lower the pressure around the package, or raise it inside, and watch what the package does.
With a CDV vacuum chamber, what changes from one method to the next is the control module and sometimes an accessory, not the principle. This page helps you pick the method for your package and sends you to the detailed guide for each one. New to the topic? Start with the package leak tester guide.
Which Method for Which Package
Start from what is inside the package and what you need to know. If your package is not here, send us a sample.
Gas inside, no liquid
Immersion bubble test under ASTM D3078. Read the ASTM D3078 leak tester guide, or the flexible packaging leak tester page for pouches, bags and flow packs.
Liquid, gel or paste
A dry test: watch for spills or seepage instead of bubbles. See the pouch and sachet leak tester.
Almost no air inside
Internal pressurization in a water bath (ASTM F2096). For vacuum-packed food, see vacuum-packed fish, ASTM F2096; for the kit, the internal pressurization kit.
Blister, sterile or pharmaceutical
Dye ingress, alone or with bubbles. See the blister pack leak tester and sterile product package integrity testing.
Shipped by air or over mountains
A reduced-pressure cycle (ASTM D6653). Read ASTM D6653 for packaging integrity during transportation.
Seal strength of a pouch
Pouch seal opening under vacuum shows the pressure at which the seal opens. See below.
Not sure which standard applies to your product? The series on leak testing methods by package type compares them by package.
Package Leak Testing Methods Compared
The same chamber runs all of these methods. What differs is whether the package needs gas inside, what you observe, and how far the result can be trusted on its own.
| Method | Standard | Gas needed inside the pack? | What you see | Result type |
|---|---|---|---|---|
| Immersion bubble test (bubble emission test) | ASTM D3078 | Yes | Bubbles from the leak point under water | Visual, probabilistic |
| Dry test | No standard named | No | Liquid or product on a paper towel | Visual |
| Internal pressurization | ASTM F2096 | No | Bubbles from a pressurized pack under water | Visual, probabilistic |
| Altitude simulation | ASTM D6653 | Depends on the pack | How the pack behaves at reduced pressure | Not a leak test by itself |
| Rigid container transport integrity | ASTM D4991 | Empty rigid containers | Leakage under vacuum | Method-dependent |
| Dye ingress | USP <1207> (reference) | No | Dye inside the package | Visual, probabilistic |
| Pouch seal opening | No standard named | Yes | The vacuum at which the seal opens | Seal strength, destructive |
Technical note: visual methods depend on the operator and are probabilistic in the USP <1207.2> sense. They are not a substitute for a deterministic method such as vacuum decay (ASTM F2338) when your risk assessment asks for one. See probabilistic and deterministic methods.
Package Leak Detection
Samples without liquid. Immersion testing to observe bubbles escaping through leaks in the packaging material or seal. This is the bubble emission test: gas inside the pack expands under vacuum, and if a path exists it leaves as a stream of bubbles under water.
Samples containing liquid. Dry testing, without immersion, to observe liquid spills or seepage. A white paper towel under the sample shows where product crosses a seal.
Detection is visual and depends on the operator's interpretation, so the vacuum level and hold time must be validated with known defects.
- ASTM D3078 leak testerThe bubble test explained.
- Bubble leak testerImmersion vacuum chambers.
- Vacuum level and test timeHow to define them.
- Do not use ASTM D3078 without reading thisLimits of the method.
- PET bottle leak testingASTM D5094 versus D3078.
- Flexible packaging leak testerPouches, bags and flow packs.
- Blister pack leak testerThermoformed packs.
- How to detect leaks in packagingAn overview.
Internal Pressurization for Vacuum-Packed Products
The additional kit allows compressed air to be injected through a needle for immersion testing. It suits packs with little or no usable headspace, such as vacuum-packed food, sachets and stick packs, and it shows where the pack leaks. The test is destructive.
- Internal pressurization kitASTM F2096 bubble test.
- Test pressure and observation timeHow to define them.
- Tyvek packsBlocking the porous side.
- Control samplesCalibrated pin or tungsten filament.
- Internal pressurization and burst testingOne protocol.
- Pouch and sachet leak testerDry test or pressurization for small packs.
Atmospheric Pressure Variation
Applications under reduced atmospheric pressure and, optionally, positive pressure. Ask about the configuration suitable for your test.
Pouch Seal Opening
Vacuum is applied until the seal ruptures. The result shows the pressure at which a seal opens, which also helps you set a safe vacuum level for the other tests on this page. The test is destructive.
Dye Ingress and Pharmaceutical Methods
When the question is whether a liquid can enter a sterile package, a dye ingress test is used instead of, or together with, bubble emission.
Chambers, Control Modules and Other Uses
The method is set by the control module and the accessories; the chamber sets the size of the sample.
- Control modules. Model M (manual), Model S (vacuum regulation and timer) and Model P (recipes and test records).
- Chambers. Bench top CDV BT, floor stand CDV FS, semi-automatic, automatic and PLC versions. The full range is on the vacuum leak testers for packaging page.
- Desiccator. With our vertical CDV chambers.
- Preservation chamber. Vacuum preservation of objects or documents to prevent contact with substances in the air, for example to prevent oxidation.
- Cosmetics. Vacuum chamber testing in cosmetics.
- Other uses. Scientific experiments, laser applications under vacuum, removal of air bubbles from silicone molds and more.
Package Leak Testing Methods FAQ
The main methods are the immersion bubble test (ASTM D3078), the dry test for liquid-filled packs, internal pressurization in a water bath (ASTM F2096), reduced-pressure simulation (ASTM D6653), pouch seal opening and dye ingress. A CDV vacuum chamber runs them with the right control module and accessories. Pick the method by what is inside the package and what you need to know.
A dry test, without immersion: lay the sample on a white paper towel, apply vacuum and watch for spills or seepage. Immersion rarely suits liquids, gels or pastes, because little gas forms bubbles and outside water can mask a weep.
The internal pressurization kit. It injects compressed air through a needle while the pack is under water. The kit's inlet accepts a maximum of 2 bar (29 psi) and is supplied with a pressure reducer.
No. Detection is visual and depends on the operator's interpretation. Validate the vacuum level and hold time with packs that have known defects, and write them into your procedure.
It depends on the method. Immersion wets the pack, internal pressurization punctures it, seal opening ruptures the seal, and a dry test can leave a pack that passed intact. Plan your sample size around the packs you will lose.
Yes. The test is free: send your samples and you receive a video of the tests performed and recommendations on test parameters.
Send us your samples