Manual control with digital measurement.
Model M does not use recipes or automatic setpoint regulation. The operator adjusts the valve, follows the gauge, controls the test duration and completes the cycle according to the written procedure.
It is designed for teams that value direct operation and lower system complexity over automation and electronic documentation.
Load and close
Place the sample in the selected CDV chamber and secure the lid according to the operating procedure.
Apply vacuum
Use the manual regulator to increase vacuum while monitoring the package and digital reading.
Hold and observe
Maintain the specified condition for the defined time and evaluate the visual indication required by the method.
Release and document
End the test manually, vent the chamber and record the result through the facility's established process.
Explore the Model M system.





Use the arrows, swipe on mobile or scroll horizontally to view the gallery.

See the manual workflow in operation.
Simple hardware, clearly defined responsibility.
Choose Model M when...
- Tests are occasional or routine
- A trained operator runs the method
- Manual timing is acceptable
- Electronic recipes are unnecessary
- Direct adjustment is preferred
- Lower system complexity is valuable
Repeatability note: A digital gauge does not make the entire test automatic. Results also depend on the procedure, operator training, vacuum target, timing, package condition and acceptance criteria.
Manual, semi-automatic or PLC control?
Compare the hardware and select the level of regulation, repeatability and documentation required by your process.
Model M

Manual vacuum regulation, digital gauge monitoring and operator-controlled timing. Best when simplicity is the priority.
Model M →Model S

Automatic vacuum regulation and controlled test time for more repeatable cycles without an advanced PLC workflow.
Model S →Model P

Recipes, permissions, automated sequences and application-dependent data or reporting functions.
Model P →Model M FAQ
Does Model M regulate vacuum automatically?
No. Vacuum adjustment is manual. The operator uses the valve and follows the digital gauge.
Does “manual” mean the gauge is mechanical?
No. Model M includes a digital vacuum indication, while regulation and cycle control remain manual.
Does Model M save recipes or test records?
No. Teams requiring stored recipes, user permissions or electronic records should evaluate Model P.
Can Model M be used with different CDV chambers?
It is designed for compatible CDV chambers. The final configuration must match the chamber, vacuum source, package and application.
Test Model M with your real package.
Send your samples and requirements so DVACI can evaluate chamber size, test conditions and system fit.