{"id":1703,"date":"2026-01-28T17:15:58","date_gmt":"2026-01-28T16:15:58","guid":{"rendered":"https:\/\/www.dvaci.com\/fr\/?p=1703"},"modified":"2026-01-28T17:15:58","modified_gmt":"2026-01-28T16:15:58","slug":"nouveau-cdv-pharma-tests-de-penetration-de-colorant-sous-vide-et-sous-pression-pour-lemballage-pharmaceutique","status":"publish","type":"post","link":"https:\/\/www.dvaci.com\/fr\/nouveau-cdv-pharma-tests-de-penetration-de-colorant-sous-vide-et-sous-pression-pour-lemballage-pharmaceutique\/","title":{"rendered":"Nouveau CDV Pharma | Tests de p\u00e9n\u00e9tration de colorant sous vide et sous pression pour l&#8217;emballage pharmaceutique"},"content":{"rendered":"<p><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_2_5 2_5 fusion-two-fifth fusion-column-first\" style=\"--awb-bg-size:cover;--awb-margin-top:20px;--awb-margin-bottom:2px;width:40%;width:calc(40% - ( ( 4% ) * 0.4 ) );margin-right: 4%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-title title fusion-title-1 fusion-sep-none fusion-title-text fusion-title-size-two\" style=\"--awb-text-color:#005d8c;--awb-font-size:50px;\"><h2 class=\"fusion-title-heading title-heading-left\" style=\"font-family:&quot;Oswald&quot;;font-style:normal;font-weight:700;margin:0;font-size:1em;\">D\u00e9couvrez le Nouveau CDV Pharma et ses trois \u00e9volutions majeures<\/h2><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_3_5 3_5 fusion-three-fifth fusion-column-last\" style=\"--awb-overflow:hidden;--awb-bg-size:cover;--awb-border-color:#000000;--awb-border-top:3px;--awb-border-right:3px;--awb-border-bottom:3px;--awb-border-left:3px;--awb-border-style:solid;--awb-border-radius:10px 10px 10px 10px;--awb-margin-top:20px;--awb-margin-bottom:1px;width:60%;width:calc(60% - ( ( 4% ) * 0.6 ) );\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-video fusion-youtube fusion-aligncenter\" style=\"--awb-max-width:980px;--awb-max-height:540px;--awb-width:100%;\"><div class=\"video-shortcode\"><div class=\"fluid-width-video-wrapper\" style=\"padding-top:55.1%;\" ><iframe title=\"YouTube video player 1\" src=\"https:\/\/www.youtube.com\/embed\/Osn795SEQU0?wmode=transparent&autoplay=0\" width=\"980\" height=\"540\" allowfullscreen allow=\"autoplay; fullscreen\"><\/iframe><\/div><\/div><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-2 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-bg-size:cover;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-title title fusion-title-2 fusion-sep-none fusion-title-center fusion-title-text fusion-title-size-two\" style=\"--awb-text-color:#003654;--awb-font-size:60px;\"><h2 class=\"fusion-title-heading title-heading-center\" style=\"font-family:&quot;Oswald&quot;;font-style:normal;font-weight:700;margin:0;font-size:1em;\">Votre laboratoire exige <strong data-start=\"366\" data-end=\"414\">pr\u00e9cision, flexibilit\u00e9 et tra\u00e7abilit\u00e9 totale<\/strong>.<\/h2><\/div><div class=\"fusion-title title fusion-title-3 fusion-sep-none fusion-title-text fusion-title-size-three\" style=\"--awb-font-size:30px;\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"font-family:&quot;Open Sans&quot;;font-style:normal;font-weight:400;margin:0;font-size:1em;\"><p data-start=\"342\" data-end=\"490\">C\u2019est exactement pour cette raison que nous avons repens\u00e9 le CDV Pharma. Dans cet article, nous vous pr\u00e9sentons le nouveau CDV Pharma et ses trois \u00e9volutions majeures, con\u00e7ues pour r\u00e9pondre aux contraintes r\u00e9elles des laboratoires pharmaceutiques et \u00e0 l\u2019\u00e9volution constante des formats d\u2019emballage.<\/p><\/h3><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-3 fusion-parallax-none nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-background-image:url(&quot;https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/modern-laboratory-dvaci-leak-tester-2.png&quot;);--awb-background-size:cover;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-first\" style=\"--awb-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% ) * 0.33333333333333 ) );margin-right: 4%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-4 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-last\" style=\"--awb-bg-size:cover;--awb-margin-top:20px;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% ) * 0.33333333333333 ) );\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-text fusion-text-1\"><p><img decoding=\"async\" class=\"alignnone size-full wp-image-1687\" src=\"https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/revslider\/cdv3-pharma-1\/CDV-pharma-leak-detection-instrument-for-testing-pharma.png\" alt=\"\" width=\"458\" height=\"325\" srcset=\"https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/revslider\/cdv3-pharma-1\/CDV-pharma-leak-detection-instrument-for-testing-pharma-200x142.png 200w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/revslider\/cdv3-pharma-1\/CDV-pharma-leak-detection-instrument-for-testing-pharma-300x214.png 300w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/revslider\/cdv3-pharma-1\/CDV-pharma-leak-detection-instrument-for-testing-pharma-400x284.png 400w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/revslider\/cdv3-pharma-1\/CDV-pharma-leak-detection-instrument-for-testing-pharma.png 458w\" sizes=\"(max-width: 458px) 100vw, 458px\" \/><\/p>\n<\/div><div class=\"fusion-aligncenter\"><a class=\"fusion-button button-flat button-xlarge button-custom fusion-button-default button-1 fusion-button-default-span fusion-has-button-gradient\" style=\"--button_accent_color:#fcfcfc;--button_border_color:#fcfcfc;--button_accent_hover_color:#f4f3eb;--button_border_hover_color:#f4f3eb;--button_border_width-top:0px;--button_border_width-right:0px;--button_border_width-bottom:0px;--button_border_width-left:0px;--button-border-radius-top-left:28px;--button-border-radius-top-right:28px;--button-border-radius-bottom-right:28px;--button-border-radius-bottom-left:28px;--button_gradient_top_color:#004e72;--button_gradient_bottom_color:#206d8c;--button_gradient_top_color_hover:#0078ba;--button_gradient_bottom_color_hover:#0078ba;--button_text_transform:none;\" target=\"_self\" href=\"https:\/\/www.dvaci.com\/fr\/testeur-detancheite-demballage-de-produits-pharmaceutiques\/\"><span class=\"fusion-button-text\">D\u00e9couvrez CDV Pharma<\/span><\/a><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-4 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-right:30px;--awb-padding-left:30px;--awb-background-color:rgba(173,109,109,0.76);--awb-background-image:linear-gradient(0deg, #015b8c 20%,#003654 80%);--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-5 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-bg-size:cover;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-title title fusion-title-4 fusion-sep-none fusion-title-center fusion-title-text fusion-title-size-two\" style=\"--awb-text-color:#eaeaea;--awb-font-size:60px;\"><h2 class=\"fusion-title-heading title-heading-center\" style=\"font-family:&quot;Oswald&quot;;font-style:normal;font-weight:700;margin:0;font-size:1em;\">Dans cet article, vous d\u00e9couvrirez :<\/h2><\/div><div class=\"fusion-title title fusion-title-5 fusion-sep-none fusion-title-text fusion-title-size-three\" style=\"--awb-text-color:#f2f2f2;--awb-font-size:30px;\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"font-family:&quot;Open Sans&quot;;font-style:normal;font-weight:400;margin:0;font-size:1em;\"><ol>\n<li>Pourquoi le CDV Pharma a \u00e9t\u00e9 repens\u00e9.<\/li>\n<li>\u00c9volution n\u00b01 : Augmentation de la hauteur de chambre et flexibilit\u00e9 des emballages.<\/li>\n<li>\u00c9volution n\u00b02 : Module de commande ind\u00e9pendant.<\/li>\n<li>\u00c9volution n\u00b03 : Essais de fuite sous vide et sous pression.<\/li>\n<\/ol><\/h3><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-5 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-6 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-bg-size:cover;--awb-margin-top:20px;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-title title fusion-title-6 fusion-sep-none fusion-title-center fusion-title-text fusion-title-size-two\" style=\"--awb-text-color:#003654;--awb-font-size:60px;\"><h2 class=\"fusion-title-heading title-heading-center\" style=\"font-family:&quot;Oswald&quot;;font-style:normal;font-weight:700;margin:0;font-size:1em;\">Augmentation de la hauteur de chambre<\/h2><\/div><div class=\"fusion-title title fusion-title-7 fusion-sep-none fusion-title-text fusion-title-size-three\" style=\"--awb-font-size:30px;\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"font-family:&quot;Open Sans&quot;;font-style:normal;font-weight:400;margin:0;font-size:1em;\"><p data-start=\"1064\" data-end=\"1337\">Tout d\u2019abord, nous avons augment\u00e9 la hauteur interne de la chambre afin d\u2019accepter une plus grande vari\u00e9t\u00e9 de formats de produits. Des contenants plus hauts, des flacons de grand diam\u00e8tre et des emballages flexibles plus \u00e9pais peuvent d\u00e9sormais \u00eatre test\u00e9s sans limitation. Cette \u00e9volution r\u00e9pond directement aux contraintes r\u00e9elles des laboratoires et \u00e0 l\u2019\u00e9volution continue des emballages pharmaceutiques.<\/p><\/h3><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-7 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first\" style=\"--awb-bg-size:cover;--awb-margin-bottom:0px;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-title title fusion-title-8 fusion-sep-none fusion-title-text fusion-title-size-three\" style=\"--awb-font-size:30px;\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"font-family:&quot;Open Sans&quot;;font-style:normal;font-weight:400;margin:0;font-size:1em;\"><p>Malgr\u00e9 cette augmentation de hauteur, la chambre reste volontairement compacte.<\/p>\n<p>Le volume interne r\u00e9duit permet une immersion compl\u00e8te avec du bleu de m\u00e9thyl\u00e8ne tout en limitant la consommation de colorant et les co\u00fbts d\u2019exploitation.<\/p><\/h3><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-8 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last\" style=\"--awb-bg-size:cover;--awb-margin-bottom:21px;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-image-element in-legacy-container\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-1 hover-type-none\"><img decoding=\"async\" width=\"1024\" height=\"576\" title=\"New-CDV-Pharma-a-augmente\u0301-la-hauteur-interne-de-la-chambre\" src=\"https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/New-CDV-Pharma-a-augmente-la-hauteur-interne-de-la-chambre-1024x576.jpg\" alt class=\"img-responsive wp-image-1712\" srcset=\"https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/New-CDV-Pharma-a-augmente-la-hauteur-interne-de-la-chambre-200x113.jpg 200w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/New-CDV-Pharma-a-augmente-la-hauteur-interne-de-la-chambre-400x225.jpg 400w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/New-CDV-Pharma-a-augmente-la-hauteur-interne-de-la-chambre-600x338.jpg 600w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/New-CDV-Pharma-a-augmente-la-hauteur-interne-de-la-chambre-800x450.jpg 800w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/New-CDV-Pharma-a-augmente-la-hauteur-interne-de-la-chambre-1200x675.jpg 1200w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/New-CDV-Pharma-a-augmente-la-hauteur-interne-de-la-chambre.jpg 1920w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/span><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-9 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-bg-size:cover;--awb-margin-top:20px;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-title title fusion-title-9 fusion-sep-none fusion-title-center fusion-title-text fusion-title-size-two\" style=\"--awb-text-color:#003654;--awb-font-size:60px;\"><h2 class=\"fusion-title-heading title-heading-center\" style=\"font-family:&quot;Oswald&quot;;font-style:normal;font-weight:700;margin:0;font-size:1em;\">Module de commande ind\u00e9pendant<\/h2><\/div><div class=\"fusion-title title fusion-title-10 fusion-sep-none fusion-title-text fusion-title-size-three\" style=\"--awb-font-size:30px;\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"font-family:&quot;Open Sans&quot;;font-style:normal;font-weight:400;margin:0;font-size:1em;\">La deuxi\u00e8me \u00e9volution majeure est le module de commande ind\u00e9pendant. S\u00e9parer l\u2019unit\u00e9 de contr\u00f4le de la chambre am\u00e9liore les d\u00e9lais de livraison, simplifie la maintenance et prot\u00e8ge les composants \u00e9lectroniques sensibles des fluides d\u2019immersion.<\/h3><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-10 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first\" style=\"--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-title title fusion-title-11 fusion-sep-none fusion-title-text fusion-title-size-three\" style=\"--awb-font-size:30px;\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"font-family:&quot;Open Sans&quot;;font-style:normal;font-weight:400;margin:0;font-size:1em;\">Le module peut \u00e9galement \u00eatre positionn\u00e9 sur le c\u00f4t\u00e9, am\u00e9liorant l\u2019ergonomie et la s\u00e9curit\u00e9 lors de l\u2019utilisation quotidienne.<\/h3><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-11 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last\" style=\"--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-image-element in-legacy-container\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-2 hover-type-none\"><img decoding=\"async\" width=\"800\" height=\"450\" title=\"CDV-Pharma-module-de-contro\u0302le-inde\u0301pendant\" src=\"https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/CDV-Pharma-module-de-controle-independant.jpg\" alt class=\"img-responsive wp-image-1714\" srcset=\"https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/CDV-Pharma-module-de-controle-independant-200x113.jpg 200w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/CDV-Pharma-module-de-controle-independant-400x225.jpg 400w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/CDV-Pharma-module-de-controle-independant-600x338.jpg 600w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/CDV-Pharma-module-de-controle-independant.jpg 800w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/span><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-12 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-bg-size:cover;--awb-margin-top:20px;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-title title fusion-title-12 fusion-sep-none fusion-title-center fusion-title-text fusion-title-size-two\" style=\"--awb-text-color:#003654;--awb-font-size:60px;\"><h2 class=\"fusion-title-heading title-heading-center\" style=\"font-family:&quot;Oswald&quot;;font-style:normal;font-weight:700;margin:0;font-size:1em;\">Essais de fuite sous vide et sous pression<\/h2><\/div><div class=\"fusion-title title fusion-title-13 fusion-sep-none fusion-title-text fusion-title-size-three\" style=\"--awb-font-size:30px;\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"font-family:&quot;Open Sans&quot;;font-style:normal;font-weight:400;margin:0;font-size:1em;\">La troisi\u00e8me \u00e9volution concerne les capacit\u00e9s d\u2019essai. Le nouveau CDV Pharma permet d\u00e9sormais de r\u00e9aliser des essais de p\u00e9n\u00e9tration de colorant sous vide et sous pression.<\/h3><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-13 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first\" style=\"--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-title title fusion-title-14 fusion-sep-none fusion-title-text fusion-title-size-three\" style=\"--awb-font-size:30px;\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"font-family:&quot;Open Sans&quot;;font-style:normal;font-weight:400;margin:0;font-size:1em;\"><p>Les essais sous pression sont disponibles dans deux configurations :<\/p>\n<p>Pressurisation interne, conform\u00e9ment \u00e0 la norme ASTM F2096.<\/p><\/h3><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-14 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last\" style=\"--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-image-element in-legacy-container\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-3 hover-type-none\"><img decoding=\"async\" width=\"800\" height=\"450\" title=\"Nouvelle-CDV-Pharma-Pressurisation-interne\" src=\"https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/Nouvelle-CDV-Pharma-Pressurisation-interne.jpg\" alt class=\"img-responsive wp-image-1720\" srcset=\"https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/Nouvelle-CDV-Pharma-Pressurisation-interne-200x113.jpg 200w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/Nouvelle-CDV-Pharma-Pressurisation-interne-400x225.jpg 400w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/Nouvelle-CDV-Pharma-Pressurisation-interne-600x338.jpg 600w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/Nouvelle-CDV-Pharma-Pressurisation-interne.jpg 800w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/span><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-15 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first\" style=\"--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-title title fusion-title-15 fusion-sep-none fusion-title-text fusion-title-size-three\" style=\"--awb-font-size:30px;\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"font-family:&quot;Open Sans&quot;;font-style:normal;font-weight:400;margin:0;font-size:1em;\">Pressurisation externe, qui augmente consid\u00e9rablement la sensibilit\u00e9 en for\u00e7ant activement le colorant dans les d\u00e9fauts potentiels.<\/h3><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-16 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last\" style=\"--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-image-element in-legacy-container\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-4 hover-type-none\"><img decoding=\"async\" width=\"800\" height=\"450\" title=\"Nouveau-CDV-Pharma-pressurisation-externe-qui-augmente-conside\u0301rablement-la-sensibilite\u0301\" src=\"https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/Nouveau-CDV-Pharma-pressurisation-externe-qui-augmente-considerablement-la-sensibilite.jpg\" alt class=\"img-responsive wp-image-1721\" srcset=\"https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/Nouveau-CDV-Pharma-pressurisation-externe-qui-augmente-considerablement-la-sensibilite-200x113.jpg 200w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/Nouveau-CDV-Pharma-pressurisation-externe-qui-augmente-considerablement-la-sensibilite-400x225.jpg 400w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/Nouveau-CDV-Pharma-pressurisation-externe-qui-augmente-considerablement-la-sensibilite-600x338.jpg 600w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/Nouveau-CDV-Pharma-pressurisation-externe-qui-augmente-considerablement-la-sensibilite.jpg 800w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/span><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-17 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-bg-size:cover;--awb-margin-top:20px;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-title title fusion-title-16 fusion-sep-none fusion-title-text fusion-title-size-three\" style=\"--awb-font-size:30px;\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"font-family:&quot;Open Sans&quot;;font-style:normal;font-weight:400;margin:0;font-size:1em;\">Avec un seul syst\u00e8me, vous pouvez r\u00e9aliser des essais uniquement sous vide tels que ASTM D3078, des essais sous pression interne et des m\u00e9thodes combin\u00e9es vide + pression. Un seul instrument, plusieurs normes d\u2019essai.<\/h3><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-18 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-bg-size:cover;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-title title fusion-title-17 fusion-sep-none fusion-title-center fusion-title-text fusion-title-size-two\" style=\"--awb-text-color:#003654;--awb-font-size:60px;\"><h2 class=\"fusion-title-heading title-heading-center\" style=\"font-family:&quot;Oswald&quot;;font-style:normal;font-weight:700;margin:0;font-size:1em;\">Une flexibilit\u00e9 accrue dans le temps<\/h2><\/div><div class=\"fusion-title title fusion-title-18 fusion-sep-none fusion-title-text fusion-title-size-three\" style=\"--awb-font-size:30px;\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"font-family:&quot;Open Sans&quot;;font-style:normal;font-weight:400;margin:0;font-size:1em;\"><p data-start=\"2918\" data-end=\"3261\">Tous les modules de commande int\u00e8grent d\u00e9sormais une plateforme bas\u00e9e sur un automate PLC avec connectivit\u00e9 compl\u00e8te : imprimantes, lecteurs de codes-barres et QR codes, ainsi que des syst\u00e8mes externes pour la g\u00e9n\u00e9ration s\u00e9curis\u00e9e de rapports PDF avec signatures \u00e9lectroniques, enti\u00e8rement conformes \u00e0 la r\u00e9glementation CFR 21 Part 11.<\/p>\n<p data-start=\"2918\" data-end=\"3261\">Avec le nouveau CDV Pharma, ces options peuvent \u00eatre activ\u00e9es ou mises \u00e0 niveau m\u00eame apr\u00e8s l\u2019installation de la machine, offrant ainsi aux laboratoires une flexibilit\u00e9 accrue au fil du temps.<\/p><\/h3><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-19 fusion_builder_column_1_4 1_4 fusion-one-fourth fusion-column-first\" style=\"--awb-bg-size:cover;width:25%;width:calc(25% - ( ( 4% + 4% + 4% ) * 0.25 ) );margin-right: 4%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-image-element in-legacy-container\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-5 hover-type-none\"><img decoding=\"async\" width=\"300\" height=\"169\" title=\"New-CDV-Pharma-lecteurs-de-codes-barres-et-de-codes-QR\" src=\"https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/New-CDV-Pharma-lecteurs-de-codes-barres-et-de-codes-QR.jpg\" alt class=\"img-responsive wp-image-1726\" srcset=\"https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/New-CDV-Pharma-lecteurs-de-codes-barres-et-de-codes-QR-200x113.jpg 200w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/New-CDV-Pharma-lecteurs-de-codes-barres-et-de-codes-QR.jpg 300w\" sizes=\"(max-width: 800px) 100vw, 300px\" \/><\/span><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-20 fusion_builder_column_1_4 1_4 fusion-one-fourth\" style=\"--awb-bg-size:cover;width:25%;width:calc(25% - ( ( 4% + 4% + 4% ) * 0.25 ) );margin-right: 4%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-image-element in-legacy-container\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-6 hover-type-none\"><img decoding=\"async\" width=\"300\" height=\"169\" title=\"New-CDV-Pharma-imprimante-thermique\" src=\"https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/New-CDV-Pharma-imprimante-thermique.jpg\" alt class=\"img-responsive wp-image-1727\" srcset=\"https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/New-CDV-Pharma-imprimante-thermique-200x113.jpg 200w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/New-CDV-Pharma-imprimante-thermique.jpg 300w\" sizes=\"(max-width: 800px) 100vw, 300px\" \/><\/span><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-21 fusion_builder_column_1_4 1_4 fusion-one-fourth\" style=\"--awb-bg-size:cover;width:25%;width:calc(25% - ( ( 4% + 4% + 4% ) * 0.25 ) );margin-right: 4%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-image-element in-legacy-container\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-7 hover-type-none\"><img decoding=\"async\" width=\"300\" height=\"169\" title=\"New-CDV-Pharma-entie\u0300rement-conforme-a\u0300-la-CFR-21-Partie-11\" src=\"https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/New-CDV-Pharma-entierement-conforme-a-la-CFR-21-Partie-11.jpg\" alt class=\"img-responsive wp-image-1728\" srcset=\"https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/New-CDV-Pharma-entierement-conforme-a-la-CFR-21-Partie-11-200x113.jpg 200w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/New-CDV-Pharma-entierement-conforme-a-la-CFR-21-Partie-11.jpg 300w\" sizes=\"(max-width: 800px) 100vw, 300px\" \/><\/span><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-22 fusion_builder_column_1_4 1_4 fusion-one-fourth fusion-column-last\" style=\"--awb-bg-size:cover;width:25%;width:calc(25% - ( ( 4% + 4% + 4% ) * 0.25 ) );\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-image-element in-legacy-container\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-8 hover-type-none\"><img decoding=\"async\" width=\"300\" height=\"169\" title=\"New-CDV-Pharma-imprimante-matricielle\" src=\"https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/New-CDV-Pharma-imprimante-matricielle.jpg\" alt class=\"img-responsive wp-image-1729\" srcset=\"https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/New-CDV-Pharma-imprimante-matricielle-200x113.jpg 200w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/New-CDV-Pharma-imprimante-matricielle.jpg 300w\" sizes=\"(max-width: 800px) 100vw, 300px\" \/><\/span><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-23 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-bg-size:cover;--awb-margin-top:20px;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-title title fusion-title-19 fusion-sep-none fusion-title-text fusion-title-size-three\" style=\"--awb-margin-top:20px;--awb-font-size:30px;\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"font-family:&quot;Open Sans&quot;;font-style:normal;font-weight:400;margin:0;font-size:1em;\">Le CDV Pharma refl\u00e8te notre approche de conception chez DVACI : \u00e9couter les laboratoires et d\u00e9velopper des solutions adapt\u00e9es aux environnements r\u00e9els de production et de contr\u00f4le qualit\u00e9. Contactez-nous pour une vid\u00e9o de d\u00e9monstration avec votre produit ou pour toute assistance technique.<\/h3><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-6 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-right:30px;--awb-padding-left:30px;--awb-background-color:rgba(173,109,109,0.76);--awb-background-image:linear-gradient(0deg, #015b8c 20%,#003654 80%);--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-24 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-bg-size:cover;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-title title fusion-title-20 fusion-sep-none fusion-title-center fusion-title-text fusion-title-size-two\" style=\"--awb-text-color:#eaeaea;--awb-font-size:60px;\"><h2 class=\"fusion-title-heading title-heading-center\" style=\"font-family:&quot;Oswald&quot;;font-style:normal;font-weight:700;margin:0;font-size:1em;\">Nous pouvons vous aider. Contactez-nous !<\/h2><\/div><div class=\"fusion-text fusion-text-2\"><p><a href=\"https:\/\/www.dvaci.com\/fr\/contact\/\"><img decoding=\"async\" class=\"size-full wp-image-819 aligncenter\" src=\"https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/contact-form.png\" alt=\"contact form\" width=\"335\" height=\"337\" srcset=\"https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/contact-form-66x66.png 66w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/contact-form-150x150.png 150w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/contact-form-200x201.png 200w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/contact-form-298x300.png 298w, https:\/\/www.dvaci.com\/fr\/wp-content\/uploads\/contact-form.png 335w\" sizes=\"(max-width: 335px) 100vw, 335px\" \/><\/a><\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":9,"featured_media":1733,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"footnotes":"","_wp_rev_ctl_limit":""},"categories":[27,9,47,8],"tags":[205,232,51,70,238,242,240,235,225,223,229,239,230,226,231,224,234,227,233,141,237,102,222,228,241],"class_list":["post-1703","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-actualites","category-cdv","category-cdv-pharma","category-detecteur-de-fuites-emballage","tag-astm-f2096","tag-blocage-de-porosite-du-tyvek","tag-cdv-pharma","tag-chambre-a-vide-cdv","tag-controle-de-qualite-pharmaceutique","tag-d3078","tag-emballage-medical","tag-emballages-pharmaceutiques","tag-emballages-steriles","tag-essai-de-bulles","tag-essai-de-detection-de-bulles","tag-essai-de-fuite-sur-tyvek","tag-essai-detancheite","tag-essais-de-fuite","tag-essais-dintegrite","tag-etancheite-des-emballages","tag-glycerine-dans-les-essais","tag-iso-11607","tag-mousse-desinfectante","tag-solutions-chambre-a-vide","tag-sterilite","tag-tests-en-chambre-a-vide","tag-tyvek","tag-validation-des-emballages","tag-validation-pharmaceutique"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.dvaci.com\/fr\/wp-json\/wp\/v2\/posts\/1703","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dvaci.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dvaci.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dvaci.com\/fr\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dvaci.com\/fr\/wp-json\/wp\/v2\/comments?post=1703"}],"version-history":[{"count":5,"href":"https:\/\/www.dvaci.com\/fr\/wp-json\/wp\/v2\/posts\/1703\/revisions"}],"predecessor-version":[{"id":1732,"href":"https:\/\/www.dvaci.com\/fr\/wp-json\/wp\/v2\/posts\/1703\/revisions\/1732"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dvaci.com\/fr\/wp-json\/wp\/v2\/media\/1733"}],"wp:attachment":[{"href":"https:\/\/www.dvaci.com\/fr\/wp-json\/wp\/v2\/media?parent=1703"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dvaci.com\/fr\/wp-json\/wp\/v2\/categories?post=1703"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dvaci.com\/fr\/wp-json\/wp\/v2\/tags?post=1703"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}