{"id":2005,"date":"2026-07-04T16:51:36","date_gmt":"2026-07-04T16:51:36","guid":{"rendered":"https:\/\/www.dvaci.com\/es\/?p=2005"},"modified":"2026-10-13T16:23:39","modified_gmt":"2026-10-13T16:23:39","slug":"astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500","status":"publish","type":"post","link":"https:\/\/www.dvaci.com\/es\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\/","title":{"rendered":"ASTM F2338: Prueba de Fugas No Destructiva | TSC 500"},"content":{"rendered":"<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1331.2px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><article class=\"dvaci-f2338\" id=\"dvaciF2338\">\n\n    <!-- =========================================================\n         ARTICLE HEADER \n         IMPORTANTE:\n         Avada ya genera el H1 principal del post.\n         Por eso aqu\u00ed usamos H2 para evitar m\u00faltiples H1.\n    ========================================================== -->\n\n    <div class=\"f2338-badge\">\n        ASTM F2338 \u00b7 Prueba de fugas por decaimiento de vac\u00edo\n    <\/div>\n\n    <h2 class=\"f2338-opening-title\">\n        ASTM F2338: prueba de fugas no destructiva para viales y botellas \u2014 TSC 500\n    <\/h2>\n\n\n    <!-- =========================================================\n         VIDEO\n    ========================================================== -->\n\n    <div class=\"f2338-video-wrapper\">\n\n        <div class=\"f2338-video-container\">\n\n            <iframe\n                src=\"https:\/\/www.youtube.com\/embed\/jK_LIFzCMek\"\n                title=\"ASTM F2338 Prueba de Fugas No Destructiva para Viales y Botellas - TSC 500\"\n                allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\"\n                referrerpolicy=\"strict-origin-when-cross-origin\"\n                allowfullscreen>\n            <\/iframe>\n\n        <\/div>\n\n    <\/div>\n\n\n    <!-- =========================================================\n         INTRO\n    ========================================================== -->\n\n    <div class=\"f2338-intro\">\n\n        <p>\n            <strong>La prueba de fugas por decaimiento de vac\u00edo seg\u00fan ASTM F2338<\/strong>\n            ofrece un m\u00e9todo no destructivo para detectar fugas en empaques adecuados mediante la medici\u00f3n de cambios de presi\u00f3n dentro de una c\u00e1mara de prueba sometida a vac\u00edo.\n        <\/p>\n\n        <p>\n            Para aplicaciones farmac\u00e9uticas como\n            <strong>viales, botellas y peque\u00f1os contenedores r\u00edgidos<\/strong>, decaimiento de vac\u00edo proporciona una medici\u00f3n f\u00edsica objetiva sin requerir inmersi\u00f3n en agua, ingreso de colorante ni inspecci\u00f3n visual destructiva.\n        <\/p>\n\n    <\/div>\n\n\n    <!-- =========================================================\n         QUICK ANSWER\n    ========================================================== -->\n\n    <section class=\"f2338-definition\">\n\n        <div class=\"f2338-definition__copy\">\n\n            <span class=\"f2338-zone-label\">\n                Respuesta t\u00e9cnica breve\n            <\/span>\n\n            <h2>\n                \u00bfQu\u00e9 es ASTM F2338?\n            <\/h2>\n\n            <p>\n                Seg\u00fan la\n                <a\n                    href=\"https:\/\/store.astm.org\/f2338-24.html\"\n                    target=\"_blank\"\n                    rel=\"noopener noreferrer\"\n                    title=\"Norma oficial ASTM F2338-24\"\n                >\n                    norma oficial ASTM F2338-24\n                <\/a>, decaimiento de vac\u00edo es un m\u00e9todo no destructivo para detectar fugas en empaques mediante el monitoreo de cambios de presi\u00f3n dentro de una c\u00e1mara de prueba sometida a vac\u00edo.\n            <\/p>\n\n            <p>\n                El empaque se coloca dentro de una c\u00e1mara de prueba sellada. Despu\u00e9s de generar el vac\u00edo, el sistema monitorea el comportamiento de la presi\u00f3n durante un periodo definido.\n            <\/p>\n\n            <p>\n                Un empaque con fugas puede permitir que gas o vapor ingrese en la c\u00e1mara sometida a vac\u00edo y produzca un cambio de presi\u00f3n medible.\n            <\/p>\n\n        <\/div>\n\n\n        <div class=\"f2338-definition__facts\">\n\n            <div>\n\n                <strong>\n                    No destructivo\n                <\/strong>\n\n                <span>\n                    Los envases adecuados pueden permanecer intactos despu\u00e9s de la inspecci\u00f3n.\n                <\/span>\n\n            <\/div>\n\n            <div>\n\n                <strong>\n                    Medici\u00f3n f\u00edsica\n                <\/strong>\n\n                <span>\n                    El m\u00e9todo mide los cambios de presi\u00f3n a lo largo del tiempo.\n                <\/span>\n\n            <\/div>\n\n            <div>\n\n                <strong>\n                    Aprobado \/ Rechazado\n                <\/strong>\n\n                <span>\n                    Los resultados se eval\u00faan con respecto a criterios de prueba definidos.\n                <\/span>\n\n            <\/div>\n\n        <\/div>\n\n    <\/section>\n\n\n    <!-- =========================================================\n         IMAGE 1\n         NON-DESTRUCTIVE APPLICATION\n    ========================================================== -->\n\n    <section class=\"f2338-section f2338-media-row\">\n\n        <div class=\"f2338-media-copy\">\n\n            <div class=\"f2338-section-heading\">\n\n                <span class=\"eyebrow\">\n                    Integridad de empaques farmac\u00e9uticos\n                <\/span>\n\n                <h2>\n                    Detecci\u00f3n de fugas no destructiva para peque\u00f1os contenedores farmac\u00e9uticos\n                <\/h2>\n\n            <\/div>\n\n            <p>\n                Los equipos de calidad farmac\u00e9utica suelen necesitar inspeccionar productos de alto valor y muestras de producci\u00f3n sin da\u00f1ar el empaque evaluado.\n            <\/p>\n\n            <p>\n                Decaimiento de vac\u00edo puede ofrecer una alternativa no destructiva para contenedores r\u00edgidos y no porosos adecuados, como viales y botellas farmac\u00e9uticas.\n            <\/p>\n\n            <ul class=\"f2338-check-list\">\n\n                <li>Viales farmac\u00e9uticos<\/li>\n                <li>Botellas peque\u00f1as<\/li>\n                <li>Contenedores r\u00edgidos no porosos<\/li>\n                <li>Muestras de alto valor<\/li>\n                <li>Muestras de control de calidad rutinario<\/li>\n\n            <\/ul>\n\n        <\/div>\n\n\n        <figure class=\"f2338-figure\">\n\n            <img\n                src=\"https:\/\/www.dvaci.com\/wp-content\/uploads\/TSC-500-Non-Destructive-Leak-Detection-for-Small-Pharmaceutical-Containers.webp\"\n                alt=\"TSC 500 realizando pruebas de fugas por decaimiento de vac\u00edo seg\u00fan ASTM F2338 en contenedores farmac\u00e9uticos\"\n                loading=\"eager\"\n                decoding=\"async\"\n            >\n\n            <figcaption>\n                Prueba de fugas no destructiva por decaimiento de vac\u00edo para peque\u00f1os contenedores farmac\u00e9uticos con el TSC 500.\n            <\/figcaption>\n\n        <\/figure>\n\n    <\/section>\n\n\n    <!-- =========================================================\n         HOW IT WORKS\n    ========================================================== -->\n\n    <section class=\"f2338-section\">\n\n        <div class=\"f2338-section-heading\">\n\n            <span class=\"eyebrow\">\n                Principio de decaimiento de vac\u00edo\n            <\/span>\n\n            <h2>\n                C\u00f3mo funciona la prueba por decaimiento de vac\u00edo seg\u00fan ASTM F2338\n            <\/h2>\n\n            <p>\n                Decaimiento de vac\u00edo convierte la integridad del empaque en una respuesta de presi\u00f3n medible dentro de una c\u00e1mara de prueba controlada.\n            <\/p>\n\n        <\/div>\n\n\n        <div class=\"f2338-method-grid\">\n\n            <article class=\"f2338-method-card\">\n\n                <span class=\"f2338-method-number\">01<\/span>\n\n                <span class=\"f2338-method-tag\">\n                    C\u00e1mara\n                <\/span>\n\n                <h3>\n                    Colocar el empaque\n                <\/h3>\n\n                <p>\n                    El vial, la botella u otro envase adecuado se coloca dentro de una c\u00e1mara configurada seg\u00fan su geometr\u00eda.\n                <\/p>\n\n            <\/article>\n\n\n            <article class=\"f2338-method-card\">\n\n                <span class=\"f2338-method-number\">02<\/span>\n\n                <span class=\"f2338-method-tag\">\n                    Vac\u00edo\n                <\/span>\n\n                <h3>\n                    Generaci\u00f3n de vac\u00edo\n                <\/h3>\n\n                <p>\n                    La presi\u00f3n alrededor del empaque se reduce hasta alcanzar la condici\u00f3n de prueba programada.\n                <\/p>\n\n            <\/article>\n\n\n            <article class=\"f2338-method-card\">\n\n                <span class=\"f2338-method-number\">03<\/span>\n\n                <span class=\"f2338-method-tag\">\n                    Estabilizaci\u00f3n\n                <\/span>\n\n                <h3>\n                    Estabilizar el sistema\n                <\/h3>\n\n                <p>\n                    Se permite que los efectos iniciales de presi\u00f3n se estabilicen antes de comenzar el periodo de medici\u00f3n.\n                <\/p>\n\n            <\/article>\n\n\n            <article class=\"f2338-method-card\">\n\n                <span class=\"f2338-method-number\">04<\/span>\n\n                <span class=\"f2338-method-tag\">\n                    Medici\u00f3n\n                <\/span>\n\n                <h3>\n                    Medir el cambio de presi\u00f3n\n                <\/h3>\n\n                <p>\n                    El sistema monitorea el comportamiento de la presi\u00f3n durante el intervalo de medici\u00f3n definido.\n                <\/p>\n\n            <\/article>\n\n        <\/div>\n\n    <\/section>\n\n\n    <!-- =========================================================\n         IMAGE 2\n         ASTM APPLICATIONS\n    ========================================================== -->\n\n    <section class=\"f2338-section f2338-media-row reverse\">\n\n        <div class=\"f2338-media-copy\">\n\n            <div class=\"f2338-section-heading\">\n\n                <span class=\"eyebrow\">\n                    Aplicaciones de ASTM F2338\n                <\/span>\n\n                <h2>\n                    Aplicaci\u00f3n de decaimiento de vac\u00edo a viales y botellas\n                <\/h2>\n\n            <\/div>\n\n            <p>\n                ASTM F2338 no se limita exclusivamente a viales y botellas farmac\u00e9uticas, pero estos contenedores r\u00edgidos y no porosos constituyen una aplicaci\u00f3n importante de la prueba por decaimiento de vac\u00edo.\n            <\/p>\n\n            <p>\n                La c\u00e1mara, el dispositivo de sujeci\u00f3n, la geometr\u00eda del empaque y las condiciones de prueba seleccionadas funcionan conjuntamente como un sistema de medici\u00f3n completo.\n            <\/p>\n\n            <p>\n                Por ello, los mismos par\u00e1metros de prueba no deben aplicarse autom\u00e1ticamente a todos los formatos de envase.\n            <\/p>\n\n        <\/div>\n\n\n        <figure class=\"f2338-figure\">\n\n            <img\n                src=\"https:\/\/www.dvaci.com\/wp-content\/uploads\/TSC-500-Applications-covered-by-ASTM-F2338.webp\"\n                alt=\"Aplicaciones de decaimiento de vac\u00edo seg\u00fan ASTM F2338 para viales y botellas farmac\u00e9uticas\"\n                loading=\"lazy\"\n                decoding=\"async\"\n            >\n\n            <figcaption>\n                Las aplicaciones habituales de decaimiento de vac\u00edo deben evaluarse seg\u00fan la geometr\u00eda del empaque, el producto y los requisitos de prueba.\n            <\/figcaption>\n\n        <\/figure>\n\n    <\/section>\n\n\n    <!-- =========================================================\n         MEASUREMENT CYCLE\n    ========================================================== -->\n\n    <section class=\"f2338-measurement-strip\">\n\n        <span class=\"f2338-strip-label\">\n            Ciclo de prueba controlado\n        <\/span>\n\n        <h2>\n            Desde la generaci\u00f3n de vac\u00edo hasta la decisi\u00f3n de aprobado o rechazado\n        <\/h2>\n\n\n        <div class=\"f2338-measurement-steps\">\n\n            <div>\n\n                <strong>\n                    Vac\u00edo\n                <\/strong>\n\n                <span>\n                    La c\u00e1mara alcanza la condici\u00f3n de vac\u00edo programada.\n                <\/span>\n\n            <\/div>\n\n\n            <div>\n\n                <strong>\n                    Estabilizaci\u00f3n\n                <\/strong>\n\n                <span>\n                    Se permite que los efectos iniciales de la presi\u00f3n y del empaque se estabilicen.\n                <\/span>\n\n            <\/div>\n\n\n            <div>\n\n                <strong>\n                    Prueba\n                <\/strong>\n\n                <span>\n                    Se mide el comportamiento de la presi\u00f3n durante el intervalo definido.\n                <\/span>\n\n            <\/div>\n\n\n            <div>\n\n                <strong>\n                    Verificaci\u00f3n\n                <\/strong>\n\n                <span>\n                    La respuesta medida se compara con los criterios de prueba.\n                <\/span>\n\n            <\/div>\n\n\n            <div>\n\n                <strong>\n                    Retorno a presi\u00f3n atmosf\u00e9rica\n                <\/strong>\n\n                <span>\n                    La c\u00e1mara regresa a la presi\u00f3n atmosf\u00e9rica para retirar las muestras.\n                <\/span>\n\n            <\/div>\n\n        <\/div>\n\n    <\/section>\n\n\n    <!-- =========================================================\n         IMAGE 3\n         REPEATABILITY\n    ========================================================== -->\n\n    <section class=\"f2338-section f2338-media-row\">\n\n        <div class=\"f2338-media-copy\">\n\n            <div class=\"f2338-section-heading\">\n\n                <span class=\"eyebrow\">\n                    Repetibilidad de la medici\u00f3n\n                <\/span>\n\n                <h2>\n                    Mediciones de decaimiento de vac\u00edo confiables y repetibles\n                <\/h2>\n\n            <\/div>\n\n            <p>\n                La repetibilidad es fundamental cuando el mismo procedimiento de prueba se realiza en distintos lotes, con diferentes operadores y turnos de control de calidad.\n            <\/p>\n\n            <p>\n                Los periodos controlados de generaci\u00f3n de vac\u00edo, estabilizaci\u00f3n y medici\u00f3n ayudan a reducir variaciones no deseadas entre ciclos de prueba consecutivos.\n            <\/p>\n\n            <p>\n                El objetivo no es simplemente generar vac\u00edo, sino crear una condici\u00f3n de medici\u00f3n repetible que permita tomar decisiones fundamentadas sobre la integridad del empaque.\n            <\/p>\n\n        <\/div>\n\n\n        <figure class=\"f2338-figure\">\n\n            <img\n                src=\"https:\/\/www.dvaci.com\/wp-content\/uploads\/TSC-500-Reliable-and-repeatable-leak-testing-measurements.webp\"\n                alt=\"Mediciones repetibles de pruebas de fugas por decaimiento de vac\u00edo con el TSC 500\"\n                loading=\"lazy\"\n                decoding=\"async\"\n            >\n\n            <figcaption>\n                Una secuencia de prueba controlada favorece mediciones repetibles de decaimiento de vac\u00edo entre ciclos.\n            <\/figcaption>\n\n        <\/figure>\n\n    <\/section>\n\n\n    <!-- =========================================================\n         TSC 500 TECHNICAL BLOCK\n    ========================================================== -->\n\n    <section class=\"f2338-equipment-zone\">\n\n        <div class=\"f2338-equipment-copy\">\n\n            <span class=\"f2338-zone-label f2338-zone-label--blue\">\n                TSC 500\n            <\/span>\n\n            <h2>\n                La prueba por decaimiento de vac\u00edo en la pr\u00e1ctica\n            <\/h2>\n\n            <p>\n                El TSC 500 est\u00e1 dise\u00f1ado para detectar fugas en peque\u00f1os contenedores mediante una medici\u00f3n controlada basada en la presi\u00f3n.\n            <\/p>\n\n            <p>\n                Su volumen de prueba compacto, generaci\u00f3n de vac\u00edo integrada y operaci\u00f3n programable est\u00e1n orientados a los procesos de control de calidad de laboratorio e industriales.\n            <\/p>\n\n        <\/div>\n\n\n        <div class=\"f2338-equipment-specs\">\n\n            <div>\n\n                <strong>\n                    -700 mbar\n                <\/strong>\n\n                <span>\n                    Regulaci\u00f3n electr\u00f3nica de vac\u00edo\n                <\/span>\n\n            <\/div>\n\n\n            <div>\n\n                <strong>\n                    5\"\n                <\/strong>\n\n                <span>\n                    Pantalla t\u00e1ctil a color\n                <\/span>\n\n            <\/div>\n\n\n            <div>\n\n                <strong>\n                    64\n                <\/strong>\n\n                <span>\n                    Programas de prueba almacenados\n                <\/span>\n\n            <\/div>\n\n\n            <div>\n\n                <strong>\n                    4\n                <\/strong>\n\n                <span>\n                    Contenedores por ciclo\n                <\/span>\n\n            <\/div>\n\n        <\/div>\n\n    <\/section>\n\n\n    <!-- =========================================================\n         IMAGE 4\n         SEALING \/ DRAWER\n    ========================================================== -->\n\n    <section class=\"f2338-section f2338-media-row reverse\">\n\n        <div class=\"f2338-media-copy\">\n\n            <div class=\"f2338-section-heading\">\n\n                <span class=\"eyebrow\">\n                    Dise\u00f1o de la c\u00e1mara de prueba\n                <\/span>\n\n                <h2>\n                    Sellado y posicionamiento de muestras consistentes\n                <\/h2>\n\n            <\/div>\n\n            <p>\n                Las mediciones repetibles dependen del sensor y del software, as\u00ed como del posicionamiento del empaque y de la consistencia del sellado de la c\u00e1mara de prueba.\n            <\/p>\n\n            <p>\n                El sistema de cierre tipo caj\u00f3n ofrece un procedimiento mec\u00e1nico consistente para cargar la muestra y cerrar la c\u00e1mara de medici\u00f3n.\n            <\/p>\n\n            <p>\n                Esto ayuda a reducir las variaciones asociadas al operador durante las pruebas rutinarias.\n            <\/p>\n\n        <\/div>\n\n\n        <figure class=\"f2338-figure\">\n\n            <img\n                src=\"https:\/\/www.dvaci.com\/wp-content\/uploads\/TSC-500-Sealing-mechanics-and-a-drawer-based-closing-system.webp\"\n                alt=\"C\u00e1mara de prueba por decaimiento de vac\u00edo del TSC 500 con sistema de sellado y cierre tipo caj\u00f3n\"\n                loading=\"lazy\"\n                decoding=\"async\"\n            >\n\n            <figcaption>\n                La operaci\u00f3n con cierre tipo caj\u00f3n ayuda a mantener un posicionamiento consistente de la muestra y un sellado uniforme de la c\u00e1mara.\n            <\/figcaption>\n\n        <\/figure>\n\n    <\/section>\n\n\n    <!-- =========================================================\n         INDUSTRIAL FEATURES\n    ========================================================== -->\n\n    <section class=\"f2338-section\">\n\n        <div class=\"f2338-section-heading\">\n\n            <span class=\"eyebrow\">\n                Control de calidad industrial\n            <\/span>\n\n            <h2>\n                Funciones para pruebas rutinarias de fugas en contenedores farmac\u00e9uticos\n            <\/h2>\n\n            <p>\n                Un detector de fugas para producci\u00f3n tambi\u00e9n necesita operaci\u00f3n repetible, trazabilidad y herramientas pr\u00e1cticas para gestionar datos.\n            <\/p>\n\n        <\/div>\n\n\n        <div class=\"f2338-feature-grid\">\n\n            <div>\n\n                <strong>\n                    Pantalla t\u00e1ctil de 5 pulgadas\n                <\/strong>\n\n                <span>\n                    Acceda a los programas de prueba y a los par\u00e1metros de operaci\u00f3n.\n                <\/span>\n\n            <\/div>\n\n\n            <div>\n\n                <strong>\n                    64 programas de prueba\n                <\/strong>\n\n                <span>\n                    Almacene configuraciones para distintos formatos de empaque.\n                <\/span>\n\n            <\/div>\n\n\n            <div>\n\n                <strong>\n                    Exportaci\u00f3n de datos por USB\n                <\/strong>\n\n                <span>\n                    Transfiera la informaci\u00f3n de las pruebas para su documentaci\u00f3n.\n                <\/span>\n\n            <\/div>\n\n\n            <div>\n\n                <strong>\n                    Conectividad RJ45\n                <\/strong>\n\n                <span>\n                    Conexi\u00f3n de red para entornos industriales.\n                <\/span>\n\n            <\/div>\n\n\n            <div>\n\n                <strong>\n                    Bomba de vac\u00edo integrada\n                <\/strong>\n\n                <span>\n                    La generaci\u00f3n de vac\u00edo est\u00e1 integrada en el equipo.\n                <\/span>\n\n            <\/div>\n\n\n            <div>\n\n                <strong>\n                    Audit Trail\n                <\/strong>\n\n                <span>\n                    Favorece la trazabilidad del equipo y de la actividad de prueba.\n                <\/span>\n\n            <\/div>\n\n        <\/div>\n\n    <\/section>\n\n\n    <!-- =========================================================\n         IMAGE 5\n         INDUSTRIAL FEATURES\n    ========================================================== -->\n\n    <section class=\"f2338-wide-visual\">\n\n        <figure class=\"f2338-figure f2338-figure--wide\">\n\n            <img\n                src=\"https:\/\/www.dvaci.com\/wp-content\/uploads\/TSC-500-Industrial-features.webp\"\n                alt=\"Funciones industriales del TSC 500 para pruebas de fugas por decaimiento de vac\u00edo en contenedores farmac\u00e9uticos\"\n                loading=\"lazy\"\n                decoding=\"async\"\n            >\n\n            <figcaption>\n                Las funciones industriales del TSC 500 favorecen la operaci\u00f3n repetible, la gesti\u00f3n de datos y las pruebas rutinarias de control de calidad.\n            <\/figcaption>\n\n        <\/figure>\n\n    <\/section>\n\n\n    <!-- =========================================================\n         DATA FLOW\n    ========================================================== -->\n\n    <section class=\"f2338-truth-panel\">\n\n        <div class=\"f2338-truth-copy\">\n\n            <span class=\"f2338-zone-label\">\n                Datos y trazabilidad\n            <\/span>\n\n            <h2>\n                La prueba de fugas tambi\u00e9n es un proceso de datos\n            <\/h2>\n\n            <p>\n                El control de calidad farmac\u00e9utico suele requerir m\u00e1s que una simple indicaci\u00f3n de aprobado o rechazado.\n            <\/p>\n\n            <p>\n                Los programas de prueba, la actividad del sistema y los resultados de medici\u00f3n pueden formar parte de una estrategia m\u00e1s amplia de trazabilidad.\n            <\/p>\n\n            <p>\n                Funciones como los programas almacenados, la conectividad y Audit Trail pueden respaldar procesos de prueba controlados cuando se implementan dentro del sistema de calidad del usuario.\n            <\/p>\n\n        <\/div>\n\n\n        <div class=\"f2338-data-flow\">\n\n            <div>\n\n                <strong>\n                    Programa de prueba\n                <\/strong>\n\n                <span>\n                    Par\u00e1metros de prueba definidos para cada empaque.\n                <\/span>\n\n            <\/div>\n\n\n            <div>\n\n                <strong>\n                    Medici\u00f3n\n                <\/strong>\n\n                <span>\n                    Respuesta f\u00edsica de decaimiento de vac\u00edo.\n                <\/span>\n\n            <\/div>\n\n\n            <div>\n\n                <strong>\n                    Decisi\u00f3n\n                <\/strong>\n\n                <span>\n                    Comparaci\u00f3n con criterios de aceptaci\u00f3n validados.\n                <\/span>\n\n            <\/div>\n\n\n            <div>\n\n                <strong>\n                    Registro\n                <\/strong>\n\n                <span>\n                    Informaci\u00f3n trazable sobre las pruebas y el equipo.\n                <\/span>\n\n            <\/div>\n\n        <\/div>\n\n    <\/section>\n\n\n    <!-- =========================================================\n         BATCH INSPECTION INTRO\n    ========================================================== -->\n\n    <section class=\"f2338-section\">\n\n        <div class=\"f2338-section-heading\">\n\n            <span class=\"eyebrow\">\n                Inspecci\u00f3n de lotes\n            <\/span>\n\n            <h2>\n                Realizar pruebas de manera m\u00e1s eficiente sin a\u00f1adir ciclos innecesarios\n            <\/h2>\n\n        <\/div>\n\n        <p>\n            La exactitud es solo una parte de la inspecci\u00f3n farmac\u00e9utica rutinaria. Los equipos de control de calidad tambi\u00e9n pueden necesitar evaluar decenas o cientos de muestras antes de liberar un lote.\n        <\/p>\n\n        <p>\n            Cuando cada envase se prueba individualmente, el tiempo total de inspecci\u00f3n puede representar una parte considerable del proceso de control de calidad.\n        <\/p>\n\n    <\/section>\n\n\n    <!-- =========================================================\n         IMAGE 6\n         PARALLEL TESTING\n    ========================================================== -->\n\n    <section class=\"f2338-productivity-panel\">\n\n        <div class=\"f2338-productivity-copy\">\n\n            <span class=\"f2338-zone-label\">\n                Pruebas en paralelo\n            <\/span>\n\n            <h2>\n                Pruebe hasta cuatro productos al mismo tiempo\n            <\/h2>\n\n            <p>\n                Seg\u00fan la geometr\u00eda del empaque, el dise\u00f1o del dispositivo de sujeci\u00f3n y el m\u00e9todo de prueba validado, el TSC 500 puede alojar hasta cuatro productos durante un solo ciclo de prueba.\n            <\/p>\n\n            <p>\n                Las pruebas en paralelo pueden reducir el tiempo total de inspecci\u00f3n y mantener la misma secuencia de medici\u00f3n controlada.\n            <\/p>\n\n            <ul class=\"f2338-check-list\">\n\n                <li>\n                    Reducir el tiempo de inspecci\u00f3n de lotes\n                <\/li>\n\n                <li>\n                    Mejorar la productividad del operador\n                <\/li>\n\n                <li>\n                    Mantener condiciones de prueba controladas\n                <\/li>\n\n                <li>\n                    Apoyar decisiones de calidad m\u00e1s r\u00e1pidas\n                <\/li>\n\n            <\/ul>\n\n        <\/div>\n\n\n        <figure class=\"f2338-figure\">\n\n            <img\n                src=\"https:\/\/www.dvaci.com\/wp-content\/uploads\/TSC-500-Leak-test-up-to-four-products-at-the-same-time.webp\"\n                alt=\"TSC 500 probando cuatro contenedores farmac\u00e9uticos en paralelo mediante decaimiento de vac\u00edo\"\n                loading=\"lazy\"\n                decoding=\"async\"\n            >\n\n            <figcaption>\n                Las configuraciones de empaque adecuadas permiten evaluar m\u00faltiples contenedores durante el mismo ciclo de prueba por decaimiento de vac\u00edo.\n            <\/figcaption>\n\n        <\/figure>\n\n    <\/section>\n\n\n    <!-- =========================================================\n         METHOD DEVELOPMENT\n    ========================================================== -->\n\n    <section class=\"f2338-section\">\n\n        <div class=\"f2338-section-heading\">\n\n            <span class=\"eyebrow\">\n                Desarrollo del m\u00e9todo\n            <\/span>\n\n            <h2>\n                \u00bfQu\u00e9 influye en la sensibilidad de decaimiento de vac\u00edo seg\u00fan ASTM F2338?\n            <\/h2>\n\n        <\/div>\n\n        <p>\n            El desempe\u00f1o de decaimiento de vac\u00edo depende de la configuraci\u00f3n completa del empaque, el producto y el dispositivo de sujeci\u00f3n, no \u00fanicamente del detector de fugas.\n        <\/p>\n\n\n        <div class=\"f2338-factor-grid\">\n\n            <div>\n\n                <strong>\n                    Geometr\u00eda del envase\n                <\/strong>\n\n                <span>\n                    La forma del empaque y su volumen interno afectan el comportamiento de la presi\u00f3n.\n                <\/span>\n\n            <\/div>\n\n\n            <div>\n\n                <strong>\n                    Sistema de cierre\n                <\/strong>\n\n                <span>\n                    Las tapas, los tapones y los sellos generan distintas rutas potenciales de fuga.\n                <\/span>\n\n            <\/div>\n\n\n            <div>\n\n                <strong>\n                    Espacio de cabeza\n                <\/strong>\n\n                <span>\n                    El volumen interno de gas puede afectar la respuesta del empaque.\n                <\/span>\n\n            <\/div>\n\n\n            <div>\n\n                <strong>\n                    Producto\n                <\/strong>\n\n                <span>\n                    El contenido del empaque puede influir en el desarrollo del m\u00e9todo.\n                <\/span>\n\n            <\/div>\n\n\n            <div>\n\n                <strong>\n                    Nivel de vac\u00edo\n                <\/strong>\n\n                <span>\n                    La presi\u00f3n de prueba influye en el esfuerzo aplicado al empaque.\n                <\/span>\n\n            <\/div>\n\n\n            <div>\n\n                <strong>\n                    Estabilizaci\u00f3n\n                <\/strong>\n\n                <span>\n                    Una estabilizaci\u00f3n insuficiente puede generar variaciones en la medici\u00f3n.\n                <\/span>\n\n            <\/div>\n\n        <\/div>\n\n    <\/section>\n\n\n    <!-- =========================================================\n         SIGNAL \/ NOISE\n    ========================================================== -->\n\n    <section class=\"f2338-signal-panel\">\n\n        <div class=\"f2338-signal-copy\">\n\n            <span class=\"f2338-zone-label\">\n                Comportamiento real de la medici\u00f3n\n            <\/span>\n\n            <h2>\n                La se\u00f1al de fuga debe distinguirse de la variaci\u00f3n normal\n            <\/h2>\n\n            <p>\n                Decaimiento de vac\u00edo mide el comportamiento de la presi\u00f3n, pero todo sistema f\u00edsico de medici\u00f3n presenta cierta variaci\u00f3n de fondo.\n            <\/p>\n\n            <p>\n                El volumen del empaque y de la c\u00e1mara, la temperatura, la estabilizaci\u00f3n, el comportamiento del material y las caracter\u00edsticas del sensor pueden influir en la respuesta medida.\n            <\/p>\n\n            <p>\n                Por ello, los criterios de aceptaci\u00f3n deben establecerse con el empaque real y el m\u00e9todo de prueba validado.\n            <\/p>\n\n        <\/div>\n\n\n        <div class=\"f2338-signal-scale\">\n\n            <div class=\"f2338-signal-good\">\n\n                <strong>\n                    Conforme\n                <\/strong>\n\n                <span>\n                    La respuesta permanece dentro de la regi\u00f3n aceptable validada.\n                <\/span>\n\n            <\/div>\n\n\n            <div class=\"f2338-signal-margin\">\n\n                <strong>\n                    Regi\u00f3n l\u00edmite\n                <\/strong>\n\n                <span>\n                    Las respuestas peque\u00f1as se acercan al l\u00edmite pr\u00e1ctico de decisi\u00f3n.\n                <\/span>\n\n            <\/div>\n\n\n            <div class=\"f2338-signal-fail\">\n\n                <strong>\n                    Respuesta de fuga\n                <\/strong>\n\n                <span>\n                    El comportamiento medido supera el criterio validado.\n                <\/span>\n\n            <\/div>\n\n        <\/div>\n\n    <\/section>\n\n\n    <!-- =========================================================\n         METHOD COMPARISON\n    ========================================================== -->\n\n    <section class=\"f2338-section\">\n\n        <div class=\"f2338-section-heading\">\n\n            <span class=\"eyebrow\">\n                Comparaci\u00f3n de m\u00e9todos\n            <\/span>\n\n            <h2>\n                Decaimiento de vac\u00edo frente a las pruebas visuales de fugas en empaques\n            <\/h2>\n\n        <\/div>\n\n\n        <div class=\"f2338-method-comparison\">\n\n            <article>\n\n                <span>\n                    Determinista\n                <\/span>\n\n                <h3>\n                    Decaimiento de vac\u00edo\n                <\/h3>\n\n                <ul>\n\n                    <li>\n                        Mide una respuesta f\u00edsica de presi\u00f3n\n                    <\/li>\n\n                    <li>\n                        Puede ser no destructivo\n                    <\/li>\n\n                    <li>\n                        Produce datos de medici\u00f3n objetivos\n                    <\/li>\n\n                    <li>\n                        Requiere desarrollar un m\u00e9todo espec\u00edfico para la aplicaci\u00f3n\n                    <\/li>\n\n                <\/ul>\n\n            <\/article>\n\n\n            <article>\n\n                <span>\n                    Probabilista\n                <\/span>\n\n                <h3>\n                    Emisi\u00f3n de burbujas\n                <\/h3>\n\n                <ul>\n\n                    <li>\n                        Se basa en la detecci\u00f3n visual de burbujas\n                    <\/li>\n\n                    <li>\n                        Ayuda a localizar la fuga\n                    <\/li>\n\n                    <li>\n                        Normalmente utiliza inmersi\u00f3n en agua\n                    <\/li>\n\n                    <li>\n                        Es \u00fatil para muchos formatos de empaque\n                    <\/li>\n\n                <\/ul>\n\n            <\/article>\n\n\n            <article>\n\n                <span>\n                    Probabilista\n                <\/span>\n\n                <h3>\n                    Ingreso de colorante\n                <\/h3>\n\n                <ul>\n\n                    <li>\n                        Utiliza la penetraci\u00f3n de un trazador l\u00edquido\n                    <\/li>\n\n                    <li>\n                        Produce evidencia visible\n                    <\/li>\n\n                    <li>\n                        Prueba destructiva\n                    <\/li>\n\n                    <li>\n                        Se utiliza en aplicaciones farmac\u00e9uticas espec\u00edficas\n                    <\/li>\n\n                <\/ul>\n\n            <\/article>\n\n        <\/div>\n\n    <\/section>\n\n\n    <!-- =========================================================\n         CONCLUSION\n    ========================================================== -->\n\n    <p class=\"f2338-verdict\">\n        La prueba por decaimiento de vac\u00edo seg\u00fan ASTM F2338 convierte la integridad del empaque en una respuesta de presi\u00f3n medible; los resultados confiables dependen del empaque, el dispositivo de sujeci\u00f3n, los par\u00e1metros de prueba y los criterios de aceptaci\u00f3n validados.\n    <\/p>\n\n\n    <!-- =========================================================\n         FAQ\n    ========================================================== -->\n\n    <section class=\"f2338-faq\">\n\n        <div class=\"f2338-section-heading\">\n\n            <span class=\"eyebrow\">\n                Preguntas frecuentes\n            <\/span>\n\n            <h2>\n                Preguntas frecuentes sobre ASTM F2338 y decaimiento de vac\u00edo\n            <\/h2>\n\n        <\/div>\n\n\n        <dl>\n\n            <dt>\n                <strong>\n                    \u00bfQu\u00e9 es ASTM F2338?\n                <\/strong>\n            <\/dt>\n\n            <dd>\n                ASTM F2338 es un m\u00e9todo de prueba est\u00e1ndar para detectar fugas de forma no destructiva en empaques adecuados mediante decaimiento de vac\u00edo.\n            <\/dd>\n\n\n            <dt>\n                <strong>\n                    \u00bfLa prueba por decaimiento de vac\u00edo seg\u00fan ASTM F2338 es destructiva?\n                <\/strong>\n            <\/dt>\n\n            <dd>\n                Decaimiento de vac\u00edo est\u00e1 concebido como un m\u00e9todo de medici\u00f3n no destructivo cuando la configuraci\u00f3n del empaque y los par\u00e1metros de prueba seleccionados son adecuados.\n            <\/dd>\n\n\n            <dt>\n                <strong>\n                    \u00bfPuede utilizarse ASTM F2338 para viales farmac\u00e9uticos?\n                <\/strong>\n            <\/dt>\n\n            <dd>\n                Decaimiento de vac\u00edo puede aplicarse a empaques no porosos adecuados, incluidas determinadas configuraciones de viales y botellas farmac\u00e9uticas.\n            <\/dd>\n\n\n            <dt>\n                <strong>\n                    \u00bfQu\u00e9 mide un detector de fugas por decaimiento de vac\u00edo?\n                <\/strong>\n            <\/dt>\n\n            <dd>\n                El equipo mide el comportamiento de la presi\u00f3n dentro de una c\u00e1mara sometida a vac\u00edo y compara la respuesta con los criterios de aceptaci\u00f3n establecidos.\n            <\/dd>\n\n\n            <dt>\n                <strong>\n                    \u00bfQu\u00e9 afecta la sensibilidad de la prueba por decaimiento de vac\u00edo?\n                <\/strong>\n            <\/dt>\n\n            <dd>\n                La geometr\u00eda del empaque, la configuraci\u00f3n del cierre, el volumen de la c\u00e1mara, el espacio de cabeza, las caracter\u00edsticas del producto, la estabilizaci\u00f3n, el nivel de vac\u00edo y la duraci\u00f3n de la medici\u00f3n pueden influir en el desempe\u00f1o de la prueba.\n            <\/dd>\n\n\n            <dt>\n                <strong>\n                    \u00bfPueden probarse varios contenedores farmac\u00e9uticos a la vez?\n                <\/strong>\n            <\/dt>\n\n            <dd>\n                El TSC 500 permite probar m\u00faltiples contenedores en configuraciones adecuadas, incluidas configuraciones para hasta cuatro contenedores durante un ciclo.\n            <\/dd>\n\n        <\/dl>\n\n    <\/section>\n\n\n    <!-- =========================================================\n         FINAL CTA\n    ========================================================== -->\n\n    <section class=\"f2338-cta\">\n\n        <div>\n\n            <h2>\n                Eval\u00fae la prueba por decaimiento de vac\u00edo en sus productos\n            <\/h2>\n\n            <p>\n                Env\u00ede a DVACI el tipo de envase, sus dimensiones y sus requisitos de control de calidad. Nuestro equipo de aplicaciones puede ayudarle a evaluar una configuraci\u00f3n de prueba por decaimiento de vac\u00edo adecuada seg\u00fan ASTM F2338.\n            <\/p>\n\n        <\/div>\n\n\n        <a\n            href=\"https:\/\/www.dvaci.com\/es\/contacto\/\"\n            class=\"f2338-button\"\n        >\n            Solicitar una evaluaci\u00f3n de muestras\n        <\/a>\n\n    <\/section>\n\n<\/article>\n\n\n<!-- =========================================================\n     IMAGE LIGHTBOX\n     ALT corregido para el analizador SEO\n========================================================== -->\n\n<div\n    id=\"f2338Lightbox\"\n    class=\"f2338-lightbox\"\n    role=\"dialog\"\n    aria-modal=\"true\"\n    aria-hidden=\"true\"\n    aria-label=\"Imagen t\u00e9cnica ampliada\"\n>\n\n    <button\n        type=\"button\"\n        class=\"f2338-lightbox__close\"\n        aria-label=\"Cerrar imagen ampliada\"\n    >\n        \u00d7\n    <\/button>\n\n\n    <div class=\"f2338-lightbox__content\">\n\n        <img decoding=\"async\"\n            id=\"f2338LightboxImage\"\n            src=\"\"\n            alt=\"Imagen t\u00e9cnica ampliada de pruebas de fugas por decaimiento de vac\u00edo seg\u00fan ASTM F2338\"\n        >\n\n    <\/div>\n\n<\/div><\/div><\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":10,"featured_media":2017,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"footnotes":"","_wp_rev_ctl_limit":""},"categories":[20,32,15,104,49],"tags":[297,315,316,31,320,319,318,323,321,324,322,317],"dkc_standard":[],"dkc_method":[],"class_list":["post-2005","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cdv","category-control-de-ciclo","category-generador-de-vacio","category-noticias","category-probador-de-hermeticidad","tag-control-de-calidad-farmaceutico","tag-21-cfr-parte-11","tag-astm-f2338","tag-dvaci","tag-equipo-de-deteccion-de-fugas","tag-integridad-del-cierre-del-contenedor","tag-prueba-de-fugas-en-viales","tag-prueba-de-fugas-farmaceutica","tag-prueba-de-fugas-no-destructiva","tag-prueba-de-fugas-por-decaimiento-de-vacio","tag-prueba-de-integridad-de-empaques","tag-tsc-500"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.4 - aioseo.com -->\n\t<meta name=\"description\" content=\"Conozca la prueba de fugas no destructiva ASTM F2338 por decaimiento de vac\u00edo para viales y botellas farmac\u00e9uticas con el TSC 500 de DVACI.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Leonardo\"\/>\n\t<meta name=\"keywords\" content=\"cdv detector de fugas para empaques,control de ciclo,generador de vacio,noticias,probador de hermeticidad\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.dvaci.com\/es\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.4\" \/>\n\t\t<meta property=\"og:locale\" content=\"es_ES\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Detector de fuga CDV - Dvaci | Para prueba de hermeticidad de envases y empaques\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"ASTM F2338: Prueba de Fugas No Destructiva | TSC 500\" \/>\n\t\t<meta property=\"og:description\" content=\"Conozca la prueba de fugas no destructiva ASTM F2338 por decaimiento de vac\u00edo para viales y botellas farmac\u00e9uticas con el TSC 500 de DVACI.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.dvaci.com\/es\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-07-04T16:51:36+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-13T16:23:39+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary\" \/>\n\t\t<meta name=\"twitter:title\" content=\"ASTM F2338: Prueba de Fugas No Destructiva | TSC 500\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Conozca la prueba de fugas no destructiva ASTM F2338 por decaimiento de vac\u00edo para viales y botellas farmac\u00e9uticas con el TSC 500 de DVACI.\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\\\/#article\",\"name\":\"ASTM F2338: Prueba de Fugas No Destructiva | TSC 500\",\"headline\":\"ASTM F2338: Prueba de Fugas No Destructiva | TSC 500\",\"author\":{\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/author\\\/leonardo\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/wp-content\\\/uploads\\\/MiniaturaWpEsp-scaled.png\",\"width\":2560,\"height\":1438},\"datePublished\":\"2026-07-04T16:51:36+00:00\",\"dateModified\":\"2026-10-13T16:23:39+00:00\",\"inLanguage\":\"es-ES\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\\\/#webpage\"},\"articleSection\":\"CDV Detector de Fugas para empaques, Control de Ciclo, Generador de vacio, Noticias, Probador de Hermeticidad, #Control de calidad farmac\\u00e9utico, 21 CFR Parte 11, ASTM F2338, Dvaci, Equipo de detecci\\u00f3n de fugas, Integridad del cierre del contenedor, Prueba de fugas en viales, Prueba de fugas farmac\\u00e9utica, Prueba de fugas no destructiva, Prueba de fugas por decaimiento de vac\\u00edo, Prueba de integridad de empaques, TSC 500\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/#listItem\",\"position\":1,\"name\":\"Inicio\",\"item\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/category\\\/generador-de-vacio\\\/#listItem\",\"name\":\"Generador de vacio\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/category\\\/generador-de-vacio\\\/#listItem\",\"position\":2,\"name\":\"Generador de vacio\",\"item\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/category\\\/generador-de-vacio\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\\\/#listItem\",\"name\":\"ASTM F2338: Prueba de Fugas No Destructiva | TSC 500\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/#listItem\",\"name\":\"Inicio\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\\\/#listItem\",\"position\":3,\"name\":\"ASTM F2338: Prueba de Fugas No Destructiva | TSC 500\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/category\\\/generador-de-vacio\\\/#listItem\",\"name\":\"Generador de vacio\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/#organization\",\"name\":\"Detector de fuga CDV - Dvaci\",\"description\":\"Para prueba de hermeticidad de envases y empaques\",\"url\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/author\\\/leonardo\\\/#author\",\"url\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/author\\\/leonardo\\\/\",\"name\":\"Leonardo\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\\\/#webpage\",\"url\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\\\/\",\"name\":\"ASTM F2338: Prueba de Fugas No Destructiva | TSC 500\",\"description\":\"Conozca la prueba de fugas no destructiva ASTM F2338 por decaimiento de vac\\u00edo para viales y botellas farmac\\u00e9uticas con el TSC 500 de DVACI.\",\"inLanguage\":\"es-ES\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/author\\\/leonardo\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/author\\\/leonardo\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/wp-content\\\/uploads\\\/MiniaturaWpEsp-scaled.png\",\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\\\/#mainImage\",\"width\":2560,\"height\":1438},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\\\/#mainImage\"},\"datePublished\":\"2026-07-04T16:51:36+00:00\",\"dateModified\":\"2026-10-13T16:23:39+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/\",\"name\":\"Detector de fuga CDV - Dvaci\",\"description\":\"Para prueba de hermeticidad de envases y empaques\",\"inLanguage\":\"es-ES\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.dvaci.com\\\/es\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"ASTM F2338: Prueba de Fugas No Destructiva | TSC 500","description":"Conozca la prueba de fugas no destructiva ASTM F2338 por decaimiento de vac\u00edo para viales y botellas farmac\u00e9uticas con el TSC 500 de DVACI.","canonical_url":"https:\/\/www.dvaci.com\/es\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\/","robots":"max-image-preview:large","keywords":"cdv detector de fugas para empaques,control de ciclo,generador de vacio,noticias,probador de hermeticidad","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.dvaci.com\/es\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\/#article","name":"ASTM F2338: Prueba de Fugas No Destructiva | TSC 500","headline":"ASTM F2338: Prueba de Fugas No Destructiva | TSC 500","author":{"@id":"https:\/\/www.dvaci.com\/es\/author\/leonardo\/#author"},"publisher":{"@id":"https:\/\/www.dvaci.com\/es\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.dvaci.com\/es\/wp-content\/uploads\/MiniaturaWpEsp-scaled.png","width":2560,"height":1438},"datePublished":"2026-07-04T16:51:36+00:00","dateModified":"2026-10-13T16:23:39+00:00","inLanguage":"es-ES","mainEntityOfPage":{"@id":"https:\/\/www.dvaci.com\/es\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\/#webpage"},"isPartOf":{"@id":"https:\/\/www.dvaci.com\/es\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\/#webpage"},"articleSection":"CDV Detector de Fugas para empaques, Control de Ciclo, Generador de vacio, Noticias, Probador de Hermeticidad, #Control de calidad farmac\u00e9utico, 21 CFR Parte 11, ASTM F2338, Dvaci, Equipo de detecci\u00f3n de fugas, Integridad del cierre del contenedor, Prueba de fugas en viales, Prueba de fugas farmac\u00e9utica, Prueba de fugas no destructiva, Prueba de fugas por decaimiento de vac\u00edo, Prueba de integridad de empaques, TSC 500"},{"@type":"BreadcrumbList","@id":"https:\/\/www.dvaci.com\/es\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.dvaci.com\/es\/#listItem","position":1,"name":"Inicio","item":"https:\/\/www.dvaci.com\/es\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.dvaci.com\/es\/category\/generador-de-vacio\/#listItem","name":"Generador de vacio"}},{"@type":"ListItem","@id":"https:\/\/www.dvaci.com\/es\/category\/generador-de-vacio\/#listItem","position":2,"name":"Generador de vacio","item":"https:\/\/www.dvaci.com\/es\/category\/generador-de-vacio\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.dvaci.com\/es\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\/#listItem","name":"ASTM F2338: Prueba de Fugas No Destructiva | TSC 500"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.dvaci.com\/es\/#listItem","name":"Inicio"}},{"@type":"ListItem","@id":"https:\/\/www.dvaci.com\/es\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\/#listItem","position":3,"name":"ASTM F2338: Prueba de Fugas No Destructiva | TSC 500","previousItem":{"@type":"ListItem","@id":"https:\/\/www.dvaci.com\/es\/category\/generador-de-vacio\/#listItem","name":"Generador de vacio"}}]},{"@type":"Organization","@id":"https:\/\/www.dvaci.com\/es\/#organization","name":"Detector de fuga CDV - Dvaci","description":"Para prueba de hermeticidad de envases y empaques","url":"https:\/\/www.dvaci.com\/es\/"},{"@type":"Person","@id":"https:\/\/www.dvaci.com\/es\/author\/leonardo\/#author","url":"https:\/\/www.dvaci.com\/es\/author\/leonardo\/","name":"Leonardo"},{"@type":"WebPage","@id":"https:\/\/www.dvaci.com\/es\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\/#webpage","url":"https:\/\/www.dvaci.com\/es\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\/","name":"ASTM F2338: Prueba de Fugas No Destructiva | TSC 500","description":"Conozca la prueba de fugas no destructiva ASTM F2338 por decaimiento de vac\u00edo para viales y botellas farmac\u00e9uticas con el TSC 500 de DVACI.","inLanguage":"es-ES","isPartOf":{"@id":"https:\/\/www.dvaci.com\/es\/#website"},"breadcrumb":{"@id":"https:\/\/www.dvaci.com\/es\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\/#breadcrumblist"},"author":{"@id":"https:\/\/www.dvaci.com\/es\/author\/leonardo\/#author"},"creator":{"@id":"https:\/\/www.dvaci.com\/es\/author\/leonardo\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.dvaci.com\/es\/wp-content\/uploads\/MiniaturaWpEsp-scaled.png","@id":"https:\/\/www.dvaci.com\/es\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\/#mainImage","width":2560,"height":1438},"primaryImageOfPage":{"@id":"https:\/\/www.dvaci.com\/es\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\/#mainImage"},"datePublished":"2026-07-04T16:51:36+00:00","dateModified":"2026-10-13T16:23:39+00:00"},{"@type":"WebSite","@id":"https:\/\/www.dvaci.com\/es\/#website","url":"https:\/\/www.dvaci.com\/es\/","name":"Detector de fuga CDV - Dvaci","description":"Para prueba de hermeticidad de envases y empaques","inLanguage":"es-ES","publisher":{"@id":"https:\/\/www.dvaci.com\/es\/#organization"}}]},"og:locale":"es_ES","og:site_name":"Detector de fuga CDV - Dvaci | Para prueba de hermeticidad de envases y empaques","og:type":"article","og:title":"ASTM F2338: Prueba de Fugas No Destructiva | TSC 500","og:description":"Conozca la prueba de fugas no destructiva ASTM F2338 por decaimiento de vac\u00edo para viales y botellas farmac\u00e9uticas con el TSC 500 de DVACI.","og:url":"https:\/\/www.dvaci.com\/es\/astm-f2338-prueba-de-fugas-para-viales-y-botellas-tsc-500\/","article:published_time":"2026-07-04T16:51:36+00:00","article:modified_time":"2026-10-13T16:23:39+00:00","twitter:card":"summary","twitter:title":"ASTM F2338: Prueba de Fugas No Destructiva | TSC 500","twitter:description":"Conozca la prueba de fugas no destructiva ASTM F2338 por decaimiento de vac\u00edo para viales y botellas farmac\u00e9uticas con el TSC 500 de DVACI."},"aioseo_meta_data":{"post_id":"2005","title":"ASTM F2338: Prueba de Fugas No Destructiva | TSC 500","description":"Conozca la prueba de fugas no destructiva ASTM F2338 por decaimiento de vac\u00edo para viales y botellas farmac\u00e9uticas con el TSC 500 de DVACI.","keywords":null,"keyphrases":{"focus":{"keyphrase":"ASTM F2338","score":0,"analysis":[]},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"Article","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","location":null,"local_seo":null,"breadcrumb_settings":null,"limit_modified_date":false,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":{"subject":"","preview":"","content":""},"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"created":"2026-07-03 19:37:21","updated":"2026-10-16 06:20:46","seo_analyzer_scan_date":null,"focus_keyword":"ASTM F2338","additional_keywords":null,"truseo_locale":null},"_links":{"self":[{"href":"https:\/\/www.dvaci.com\/es\/wp-json\/wp\/v2\/posts\/2005","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dvaci.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dvaci.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dvaci.com\/es\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dvaci.com\/es\/wp-json\/wp\/v2\/comments?post=2005"}],"version-history":[{"count":5,"href":"https:\/\/www.dvaci.com\/es\/wp-json\/wp\/v2\/posts\/2005\/revisions"}],"predecessor-version":[{"id":2283,"href":"https:\/\/www.dvaci.com\/es\/wp-json\/wp\/v2\/posts\/2005\/revisions\/2283"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dvaci.com\/es\/wp-json\/wp\/v2\/media\/2017"}],"wp:attachment":[{"href":"https:\/\/www.dvaci.com\/es\/wp-json\/wp\/v2\/media?parent=2005"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dvaci.com\/es\/wp-json\/wp\/v2\/categories?post=2005"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dvaci.com\/es\/wp-json\/wp\/v2\/tags?post=2005"},{"taxonomy":"dkc_standard","embeddable":true,"href":"https:\/\/www.dvaci.com\/es\/wp-json\/wp\/v2\/dkc_standard?post=2005"},{"taxonomy":"dkc_method","embeddable":true,"href":"https:\/\/www.dvaci.com\/es\/wp-json\/wp\/v2\/dkc_method?post=2005"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}